Elan IRDKIT Manuel d'installation Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
©2004 Linear LLC. All Rights Reserved. 07/04. Page 27
INSTALLATION MANUAL
H560
H560 Audio Distribution Amplifier Reference Voltages
Between H560 Pins:
Voltage Should Read:
+12V (+) and SHLD/GND (G)
-12V (-) and SHLD/GND (G)
PHONE OUT TIP (to) and PHONE OUT RING (ro)
VOL CONT OVERRIDE+ (O+) and VOL CONT
DB1+(d1) or DB2+ (d2)
and DOORBELL COMMON (C)
LATCH+ (l+) and LATCH- (l-)
MIC+ (m+) and MIC- (m-)
SPEAKER+ (s+) AND SPEAKER- (s-)
IR+12V (I+) and GND (g)
MUTE SW+ (S) and SHLD/GND (G)
+12 VDC
-12 VDC
+24 VDC
12 VDC between O+ and O-
only when Page/DB is active
O+ will always read +12 VDC
to any Ground except O-
+12 VDC
+12 VDC only when #,3,0 is pressed and held
+5 VDC
0 VDC
+12 VDC
+4.75 VDC
No music
(doorchime & page ok)
1. Confirm that the audio source and the RCA
patch cord between audio source & the
Music Input Wallplate are good.
2. Be sure that Volume Controls are turned up
3. Confirm that the Input Level Adjustment pot
on the Music Input Wallplate is turned up.
4. Check for +/- 12 VDC present at the Music
Input Wallplate and verify L & R audio wires
are connected properly. If not, check the
fuses with a meter. Replace with 4A slow
blow fuses only.
5. Cycle power to the H560 by going to the
main electrical circuit panel and turning the
appropriate breaker off, waiting 30 sec-
onds, then turning the breaker back on.
If, after trying all of the above, the problem
persists, call OpenHouse Technical Support
for assistance.
Volume
Level
Adjustmen
t
Mis-wired Music Input
Wallplate.
Fuses are blown.
Symptom Possible Cause Possible Solution
Vue de la page 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 35 36

Commentaires sur ces manuels

Pas de commentaire